The Format Menu

Activity Indicators

Activity Indicators
When the logic analyzer is properly connected to an active target system, you
see either a high level dash, a low level dash, or a transitional arrow in the
Activity Indicator displays for each pod probe. These indicators are very
useful in showing proper probe connection and that the logic levels are as
expected according to the threshold level setting. The Activity Indicators are
not displayed during an acquisition.

Symbols field

Activity Indicators
Activity Indicators
Symbols Field
Symbols are used in place of ambiguous data values in data listings. A
custom symbol name, relevant to the measurement, can be easily spotted in a
long list of data.
See Also
"Symbols Assignment" chapter in the Common Module Operations section of
the Agilent Technologies 16500 Logic Analysis User's Reference for
complete information on assigning symbols.