CDE360 Vector Control AC Drive
Group A0: Monitor
Parameters in A0 group are used to facilitate the user to view the drive state, all of these parameters
are read only, users can't modify them. When using the keypad to view these parameters, the
keypad will refresh these values.
A0.00
Running
frequency
A0.01
Setting
frequency
A0.02
DC bus voltage
A0.03
Output voltage
A0.04
Output current
A0.05
Output torque
A0.06
Output power
A0.07
Motor speed
Chapter 6 Parameters Description
Range: 0.00~b0.00
Unit: Hz
It displays the absolute value of running frequency.
Range: 0.00~b0.00
Unit: Hz
It displays the absolute value of set frequency.
Range: 0.0~3000.0
Unit: V
It displays the drive's bus voltage.
Range: 0~1500
Unit: V
It displays the drive's output voltage in the running state.
Range: 0.00~655.35
Unit: A
It displays the drive's output current in the running state.
0.01A(drive Power ≤ 55kW)
0.1A(drive Power ≥ 75kW)
Range: -300.0~300.0
Unit: %
It displays the drive's output torque in the running state, the reference item
is rated motor torque.
Range: 0.1~2000.0
Unit: kW
It displays the drive's output power in the running state.
Range: 0~65535
Unit: RPM
It displays the motor's rotate speed in the running state.
Default: 0.00
86
-
-
Chapter 6 Parameters Description
Default: 0.00
Default: 0.0
Default: 0
Default: 0.00
Default: 0.0
Default: 0.0
Default: 0