Group C4: Pulse Input/Output - Canworld CDE360 Series Manual

Vector control ac drive
Table of Contents

Advertisement

CDE360 Vector Control AC Drive
output
C3.11
AO curve 2
maximum output
C3.12
Corresponding
setting of AO
curve 2
maximum output

Group C4: Pulse Input/Output

When the parameter of C0.06 set to 31, the pulse input function is enabled. The curve
relationship can be set by parameters C4.00~C4.04. The maximum pulse input signal is
100KHz, the percent reference is maximum frequency(b0.00).
C4.00
FI filter time
C4.01
FI minimum input
Range: 0.00~10.00
Unit: V
Define AO curve 2 maximal output value. When chose the 0~20mA
current input, 0mA corresponding to the 0V, and 20mA corresponding to
10V.
Range: C3.10~100.0
Unit: %
The relationship between AO curve 2 maximal input signal and the
percentage of set value.
Range: 0.00~10.00
Unit: Sec
The parameter is used to set the software filter time of FI. If the pulse input
signal is liable to interference, increase the value of this parameter to stabilize
the pulse input.
Figure 6- 19 Pulse input filter
Range: 0.00~C4.03
Unit: kHz
If the pulse input lower C4.01 then it will be limited by C4.01.
Chapter 6 Parameters Description
Default: 10.00
Default: 100.0
Default: 0.10
Default: 0.00