CDE360 Vector Control AC Drive
Steps of select monitor parameters.
Choose the parameters to be displayed.
Sum the value of every parameter bit
.Set the summation value to the related parameter.
For example,if the Running frequency, Bus voltage, and Pulses Count value need to be
displayed, H0.03 shall be set to the summation value of 32773(1+4+32768 = 32773).
The LCD keypad will show the meaning of parameters on LCD screen if the AC drive has no
fault. Change to the second line of LCD screen by press Enter, and an additional displayed
parameter can be chose.
The LCD keypad will show the meaning of fault code on LCD screen. Such as the LCD
screen will display "Current detection fault " when LED display "Er22".
When observing the monitor parameters, value of the reference determined by C0.18 can
also be changed by adjusting the rotary knob.And the keypad interface will return to show monitor
parameters again 3 seconds after the adjustment.
The keypad interface will return to show monitor parameters automatically if there is no key
pressing action in 1 minute.

4.6 Parameters Upload and Download

Parameters upload and download is a function of parameters backup and copy.It is
convenient for user configuring the parameters among AC drives.
Set H0.04 to 3 will begin uploading the parameters value to the keypad. And the LCD screen
will show 'Loading' simultaneously.
Set H0.04 to 4 will begin downloading the parameters value to the control board. And the
LCD screen will show 'Downloading' simultaneously.
Keypad will not respond any key press in whole upload or download process.After upload or
download is completed,the keypad will automatically return to normal display.And the value of
function code H0.04 will changed to 0.
Download action will be invalid if there is no data in keypad.