CDE360 Vector Control AC Drive
Group L1: Point-point Communication
①
L1.00
Master and slave
selection
①
L1.01
Send data
selection of
master
①
L1.02
Point-point
communication
enable
①
L1.03
Usage of data
received by slave
L1.04
Gain of received
data
L1.05
Zero offset of
received data
The parameter of L1.04 and L1.05 are used to calibrate the salve received data.
If L1.04 is expressed by character 'a' and the L1.05 is expressed by character 'b', the received data
is expressed by character 'x', the result used by slave is expressed by character 'y', then y=a*x+b,
the
range
Range: 0~1
0: Master
Drive send data to other external device as master.
1: Slave
Drive receive data from other external device as slave. The received data
is valid only when the conditions listed below are satisfied.
1)Command source is communication
2) Reference source is communication
Range: 0~3
It is used to set send date type of master in P2P operation.
0: Torque reference, 100% corresponds to motor rated torque(b0.00).
1: Running frequency, 100% corresponds to max frequency(b0.00).
2: Setting frequency, 100% corresponds to max frequency(b0.00).
3: Feedback frequency, 100% corresponds to max frequency(b0.00).
Range: 0~1
0: Disable
1: Enable
Range: 00~11
Unit's digit: Data usage of slave
0: As torque reference
1: As frequency reference
Ten's digit: Whether to follow the master commands
0: No
1: Yes
Range: -9.99~10.00
It is used to set the Point-to-point receive data gain for slave.
Range: -99.9~100.0
Unit: %
It is used to set the Point-to-point receive data offset for slave.
of
Chapter 6 Parameters Description
Default: 1
Default: 0
Default: 0
Default: 00
Default: 1.00
Default: 0.0
y
is
3) L1.02 = 1
4) Receive broadcast frame
-100.00%~100.00%.