Recommendation Of Brake Resistance Selection - Canworld CDE360 Series Manual

Vector control ac drive
Table of Contents

Advertisement

CDE360 Vector Control AC Drive

2.8 Recommendation of Brake Resistance Selection

AC drive voltage
&power classes
2S0R7
2S1R5
4T0R7G/1R5L
4T1R5G/2R2L
4T2R2G/3R7L
4T3R7G/5R5L
4T5R5G/7R5L
4T7R5G/011L
4T011G/015L
4T015G/018L
4T018G/022L
4T022G/030L
4T030G/037L
4T037G/045L
4T045G/055L
4T055G/075L
4T075G/090L
4T090G/110L
4T110G/132L
5T0R7G/1R5L
5T1R5G/2R2L
5T2R2G/3R7L
5T3R7G/5R5L
5T5R5G/7R5L
5T7R5G/011L
5T011G/015L
5T015G/018L
5T018G/022L
5T022G/030L
5T030G/037L
5T037G/045L
5T045G/055L
5T055G/075L
5T075G/090L
5T090G/110L
Table 2- 6 Brake resistance selection table of CDE360 series
Recommended
power(kW)
Single phase 220V input
0.15
0.2
Three phase 380V input
0.45
0.45
0.6
0.7
0.8
1
1.5
2.0
2.5
3
3.7
5
7
8.5
14
Three phase 480V input
0.45
0.45
0.6
0.7
0.8
1
1.5
2.0
2.5
3
3.7
5
7
8.5
14
Recommended
resistance(Ω)
100
75
≥ 150
≥ 150
≥ 120
≥ 100
≥ 80
≥ 65
≥ 43
≥ 32
≥ 30
≥ 24
≥ 16
≥ 14
≥ 10
≥ 8
External (Optional) 150A
≥ 5
≥ 200
≥ 200
≥ 150
≥ 120
≥ 100
≥ 75
≥ 51
≥ 39
≥ 36
≥ 29
≥ 20
≥ 18
≥ 12
≥ 10
External (Optional) 150A
≥ 6
External (Optional) 150A
Chapter 2 Product Information
Brake Unit
Built-in
Built-in (Standard)
External (Optional) 60A
External (Optional) 80A
Built-in (Standard)
External (Optional) 60A
External (Optional) 80A

Advertisement