CDE360 Vector Control AC Drive

F1 Auto Reset

Code
Name
F1.00
Fault auto reset times
F1.01
Time interval of fault auto reset
F1.02
DO action during fault auto reset
Unit's digit: Fault indication terminals
0: No action during fault reset process
Ten's digit: restart after automatic fault reset
0: Not auto restart

H0 System Parameters

Code
Name
H0.00
User password
H0.01
LED display running
parameters 1
Bit0: Running frequency(1)
Bit1: Setting frequency(2)
Bit2: Dc-link voltage(4)
Bit3: Output current(8)
Bit4: Output voltage(16)
Bit5: Output torque(32)
H0.02
LED display running
parameters 2
Bit0: FI input frequency(1)
Bit1: Linear speed(2)
Bit2: Load speed(4)
Bit3: Actual length(8)
H0.03
LED display stop
parameters
Bit0: Setting frequency(1)
Bit1: Dc-link voltage(2)
Bit2: X terminals status(4)
Bit3: Y terminals status(8)
Bit4: AI1 voltage(16)
H0.04
Parameter initial option
0: No Operation
2: Restore to factory default value, including motor parameters
3: Parameter upload to keypad
H0.05
Menu display selection
0: Display all parameters
2: Display non factory setting parameters
Range
0~30
0.1~100.0
00~11
Range
0000~9999
0~65535
Bit6: Output power(64)
Bit7: AI1 voltage(128)
Bit8: AI2 voltage(256)
Bit9: AI3 voltage(512)
Bit10: X terminals status(1024)
0~2047
Bit4: remaining running time(16)
Bit5: Main frequency A (32)
Bit7: FO output frequency(128)
1~65535
Bit5: AI2 voltage(32)
Bit6: AI3 voltage(64)
Bit7: FI input frequency(128)
Bit8: PID setting(256)
Bit9: PID feedback(512)
0~4
1: Restore to factory default value, not include motor parameters
4: Parameter download from keypad
0~2
1: Display user-defined parameters
80
-
-
Chapter 5 Parameter List Table
Default
0
1.0
00
1: Action during fault reset
1: having auto restart
Default
Step
0000
1
31
1
Bit11: Y terminals status(2048)
Bit12: PLC stage(4096)
Bit13: PID setting(8192)
Bit14: PID feedback(16384)
Bit15: Count value(32768)
0
1
Bit8:Feedback speed(256)
Bit9:motor speed(512)
Bit10:Multi-Pump Control status
words(1024)
3
1
Bit10: PLC stage(1024)
Bit11: Pulse input frequency(2048)
Bit12: actual length(4096)
Bit13~Bit15: reserve
0
1
0
1
Step
Description
1
0.1Sec
1
Description