CDE360 Vector Control AC Drive
C2 Analog Input
Function
Name
Code
C2.00
AI1 filter time
C2.01
AI2 filter time
C2.02
AI3 filter time
C2.03
AI curve selection
1: AI curve 1(C2.04~07)
Unit's digit: AI1
C2.04
AI curve 1 minimum input
C2.05
Corresponding setting of
AI curve 1 minimum input
C2.06
AI curve 1 maximum input
C2.07
Corresponding setting of
AI curve 1 maximum input
C2.08
AI curve 2 minimum input
C2.09
Corresponding setting of
AI curve 2 minimum input
C2.10
AI curve 2 maximum input
C2.11
Corresponding setting of
AI curve 2 maximum input
C2.12
AI curve 3 minimum input
C2.13
Corresponding setting of
AI curve 3 minimum input
C2.14
AI curve 3 maximum input
C2.15
Corresponding setting of
AI curve 3 maximum input
C2.16
Jump point of AI1 input
corresponding setting
C2.17
Jump amplitude of AI1 input
corresponding setting
C2.18
Jump point of AI2 input
corresponding setting
C2.19
Jump amplitude of AI2 input
corresponding setting
C2.20
Jump point of AI3 input
corresponding setting
C2.21
Jump amplitude of AI3 input
corresponding setting
Range
0.00~10.00
0.00~10.00
0.00~10.00
111~333
2: AI curve 2(C2.08~11)
Ten's digit: AI2
-10.00~C2.06
-100.0~100.0
C2.04~10.00
-100.0~100.0
-10.00~C2.10
-100.0~100.0
C2.08~10.00
-100.0~100.0
-10.00~C2.14
-100.0~100.0
C2.12~10.00
-100.0~100.0
-100.0~100.0
0.0~100.0
-100.0~100.0
0.0~100.0
-100.0~100.0
0.0~100.0
58
-
-
Chapter 5 Parameter List Table
Default
Step
0.10
0.01Sec
0.10
0.01Sec
0.10
0.01Sec
321
1
3: AI curve 3(C2.12~15)
Hundred's digit: AI3
0.00
0.01V
0.0
0.1%
10.00
0.01V
100.0
0.1%
0.00
0.01V
0.0
0.1%
10.00
0.01V
100.0
0.1%
0.00
0.01V
0.0
0.1%
10.00
0.01V
100.0
0.1%
0.0
0.1%
0.5
0.1%
0.0
0.1%
0.5
0.1%
0.0
0.1%
0.5
0.1%
Description