B2 Frequency Source - Canworld CDE360 Series Manual

Vector control ac drive
Table of Contents

Advertisement

CDE360 Vector Control AC Drive
Function
Name
Code
b1.14
Stop DC brake waiting time
b1.15
Stop DC brake current
b1.16
Stop DC brake time
b1.17
Running mode when
running frequency lower
than frequency lower limit
0: Run at frequency lower limit
1: Run at zero speed
b1.18
Running direction
It is used to set the motor direction which is consistent with the reference frequency or not, whatever the
control source is.
b1.19
Forward/Reverse rotation
dead-zone time
b1.20
Reverse prohibition
b1.21
Stop key function
0: STOP/RESET key enabled only in operation keypad control
b1.22
Startup protection
If this parameter is set to 1, even the start command is active, the AC drive will be not response to the start command. Users
should cancel the start command firstly, then send the start command again to run the AC drive.
b1.23
Dynamic brake
use ratio
The larger the value of this parameter is, the larger braking duty will be. 0% means disable dynamic brake function.
b1.24
Dynamic brake
voltage
Multi function
b1.25
of JOG key
0: JOG

b2 Frequency Source

Function
Name
Code
b2.00
Main frequency
source A
0: b2.01+UP/DOWN
1: AI1
Range
0.0~100.0
0~100
0.0~100.0
0~3
2: Stop
3: Stop, restart when setting frequency higher than lower limit
0~1
0.0~3000.0
0~1
0~1
0~1
0~100
100
Module
Module
dependent
dependent
0~2
0
1:Forward/Reverse switching
Range
0~8
2: AI2
4: X6/FI
3: AI3
5: PID
Default
Step
0.0
0.1Sec
20
1%
0.0
0.1Sec
0
1
0
1
0.0
0.1Sec
0
1
1
1
1: STOP/RESET key enabled in any operation mode
1
1
1%
0.1V
For function selection of JOG key on
1
Keypad.
Default
Step
0
1
6: PLC
7: Multi-Reference
53
-
-
Chapter 5 Parameter List Table
Description
0: Same direction
1: Reverse direction
0: Reverse enabled
1: Reverse disabled
0: No
1: Yes
2:Command source switching
Description
8: Communication