C4 Pulse Input/Output

Function
Name
Code
C4.00
FI filter time
C4.01
FI minimum input
C4.02
Corresponding setting of FI
minimum input
C4.03
FI maximum input
C4.04
Corresponding setting of FI
maximum input
C4.05
FO filter time
C4.06
FO function
C4.07
FO output minimum frequency
C4.08
Corresponding setting of FO
output minimum frequency
C4.09
FO output maximum frequency
C4.10
Corresponding setting of FO
output maximum frequency

C5 Virtual Digital Input/Output

Function
Name
Code
C5.00
VX1 function
C5.01
VX2 function
C5.02
VX3 function
C5.03
VX4 function
C5.04
VX active state mode
selection
0: Set by VYn
Unit's digit: VX1
C5.05
Digital setting of VX
active state
Unit's digit: VX1
C5.06
Active mode for AI as
VX input
Unit's digit: AI1
C5.07
Active mode for AI as
VX input
C5.08
Active mode for AI as
VX input
Range
0~58
0~58
0~58
0~58
0000~4444
1: Set by C5.05
Ten's digit: VX2
0000~1111
Ten's digit: VX2
000~111
Ten's digit: AI2
C5.08~8.00
1.00~C5.07
Range
Default
0.00~10.00
0.10
0.00~C4.03
0.00
-100.0~100.0
0.0
C4.01~100.00
50.00
-100.0~100.0
100.0
0.00~10.00
0.00
0~17
1
0.00~100.00
0.00
0.0~C4.10
0.0
0.00~100.00
50.00
C4.08~100.0
100.0
Default
0
0
0
0
1111
2: Set by AI1
Hundred's digit: VX3
0000
Hundred's digit: VX3
000
6.70
3.20
60
-
-
Chapter 5 Parameter List Table
Step
0.01Sec
0.01kHz
0.1%
0.01kHz
0.1%
0.01Sec
1
0.01kHz
0.1%
0.01kHz
0.1%
Step
Description
1
1
Same As C0.01
1
1
1
3: Set by AI2
4: Set by AI3
Thousand's digit: VX4
1
0: Active
1: Inactive
Thousand's digit: VX4
1
0: High is active
1: Low is active
Hundred's digit: AI3
0.01V
0.01V
Description
Same As C3.02

Advertisement

Table of Contents
loading