CDE360 Vector Control AC Drive

Group E3: Simple PLC

Simple PLC can complete simple combination of multi-reference.
E3.00
Simple PLC
running mode
f1
a1
T1
E3.01
Simple PLC
retentive
selection
PLC retentive upon power failure indicates that the AC drive memorizes the PLC running moment
and running frequency before power failure and will continue running from the memorized moment
after it is powered on again. If the unit's digit is set to 0, the AC drive restarts the PLC process after it
is powered on again.
Range: 0~2
Simple PLC can be either the frequency source or V/F separated voltage
source.When simple PLC is used as the frequency source, whether
parameter values of E2.01 to E2.16 are positive or negative determines
the running direction. If the parameter values are negative, it indicates that
the AC drive runs in reverse direction.
0: Stop after the AC drive runs one cycle
The AC drive stops after running one cycle, and will not start up until
receiving another command.
1: Keep final values after the AC drive runs one cycle
The AC drive keeps the final running frequency and direction after running
one cycle.
2: Repeat after the AC drive runs one cycle
The AC drive automatically starts another cycle after running one cycle,
and will not stop until receiving the stop command.
f5
f4
a5
f3
a4
f2
a3
a2
T2
T3
T4
T5
Figure 6- 33 Simple PLC when used as frequency source
Range: 00~11
Unit's digit (Retentive upon power failure)
Ten's digit (Retentive upon stop)
0: No
1: Yes
f7
f6
a7
a6
d8
a8
f8
a9
f9
a10
f10
T6
T7
T8
T9 T10 T11 T12 T13 T14 T15
Chapter 6 Parameters Description
Default: 0
f15
f14
a15
d15
f13
a14
a13
d13
f12
a11
d12
f11
Default: 00