CDE360 Vector Control AC Drive
Function
Name
Code
C5.09
VY1 function
C5.10
VY2 function
C5.11
VY3 function
C5.12
VY4 function
C5.13
VY1 output delay time
C5.14
VY2 output delay time
C5.15
VY3 output delay time
C5.16
VY4 output delay time
C5.17
VY terminal active
state logic
Unit's digit: VY1

d0 Motor Control

Function
Name
Code
d0.00
Motor control mode
0: V/f
d0.01
Carrier frequency
d0.02
Carrier frequency
adjustment with
temperature
d0.03
Random PWM depth
Random PWM can decrease motor noise without increasing carrier frequency. The bigger , the wider spectrum.
0: disable random PWM
d0.04
DPWM switchover
frequency upper limit
If the output frequency is higher than this Value + 3Hz, the DPWM modulation mode is adopted, or else
continuous method is adopted.
d0.05
PWM Modulation
mode
0: Asynchronous modulation
d0.06
Torque boost
d0.07
Cut-off frequency of
torque boost
Range
0~45
0~45
0~45
0~45
0.0~3600.0
0.0~3600.0
0.0~3600.0
0.0~3600.0
0000~1111
Ten's digit: VY2
Range
0~2
1: Open loop vector control
Module
dependent
0~1
0~10
0.00~b0.00
0~1
0.0~20.0
0.00~b0.00
Default
Step
0
1
0
1
0
1
0
1
0.0
0.1Sec
0.0
0.1Sec
0.0
0.1Sec
0.0
0.1Sec
0000
1
Hundred's digit: VY3
Default
Step
0
1
Module
0.1kHz
dependent
1
1
0
1
1~10: setting the depth of random PWM
10.00
0.01Hz
0
1
1: Synchronous modulation
Module
0.1%
dependent
37.00
0.01Hz
61
-
-
Chapter 5 Parameter List Table
Description
Same As C1.01
Same As C1.01
Same As C1.01
Same As C1.01
0: Positive logic
1: Negative logic
Thousand's digit: VY4
Description
2: Close loop vector control
0: Enabled
1: Disabled
0.0%: auto torque boost
> 0.0%: customized
torque boost