Group C2: Analog Input - Canworld CDE360 Series Manual

Vector control ac drive
Table of Contents

Advertisement

CDE360 Vector Control AC Drive
C1.22
Interval of Y1
output active
state
C1.23
Interval of Y2
output active
state
C1.24
Interval of T1
output active
state
C1.25
Interval of T2
output active
state
In some occasions, when the digital output terminals' state is effective, hopes that the output
state of the terminal is time length adjustable, and not only a level signal. The holdoff time of
terminal's effective state is only available after the output delay time.
Note: When the holdoff time of terminal's effective sate set to 0, equivalent cancel the
terminal's effective state.
Figure 6- 14 The effective signal holdoff time of digital output terminal

Group C2: Analog Input

C2.00
AI1 filter time
Range: 0.0~600.0
Unit: Sec
Define the digital output terminal Y1 output effective sate holdoff time..
Range: 0.0~600.0
Unit: Sec
Define the digital output terminal Y2 output effective sate holdoff time.
Range: 0.0~600.0
Unit: Sec
Define the relay T1 output effective sate holdoff time.
Range: 0.0~600.0
Unit: Sec
Define the relay T2 output effective sate holdoff time.
Range: 0.00~10.00
Unit: Sec
Define the filter time of analog input signal AI1, to filter processing.
Properly increasing this value can enhance the anti-interference ability of
analog input, but will weaken the sensitivity.
Chapter 6 Parameters Description
Default: 0.0
Default: 0.0
Default: 0.0
Default: 0.0
Default: 0.10