Group D3 : Torque Control - Canworld CDE360 Series Manual

Vector control ac drive
Table of Contents

Advertisement

CDE360 Vector Control AC Drive
:
Group d3
Torque Control
d3.00
Speed/Torque
control selection
d3.01
Torque reference
source
d3.02
Digital setting of
torque reference
d3.03
Torque
compensation
source
Range: 0 ~ 1
It is used to select motor control mode in vector control.
0: Speed Control
If one of the input digital terminals is set to function 35 (torque control
forbidden), speed control will be active when the terminal is active
regardless the setting of d3.00.
If one of the input digital terminals is set to function 34 (speed/torque
control switch), the actual control mode will be different with the setting of
d3.00 when the terminal is active.
Range: 0 ~ 7
0: d3.02+UP/DOWN
1: AI1
2: AI2
3: AI3
4: X6/FI
5: Communication
6: MIN(AI1,AI2)
7: MAX(AI1,AI2)
When this parameter is set to 0, the torque reference can be setting
through terminal up/down adjustment function or up/down key when
C0.18 is set to 1. When this parameter is set to none 0, 100% of the
setting corresponds to the value of d3.02.
Range: -300.0 ~ 300.0
Unit: %
Digital setting of torque reference. 100% of the setting corresponds to the
rated motor torque.
Range: 0 ~ 7
0: d3.04
1: AI1
2: AI2
3: AI3
4: X6/FI
5: Communication
6: MIN(AI1,AI2)
7: MAX(AI1,AI2)
User can choose a suitable source as torque reference compensation
according to actual application.
1: Torque Control
Chapter 6 Parameters Description
Default: 0
Default: 0
Default: 50.0
Default: 0

Advertisement

Table of Contents
loading

Table of Contents