L1 Point-Point Communication; L2 Encoder Setting - Canworld CDE360 Series Manual

Vector control ac drive
Table of Contents

Advertisement

CDE360 Vector Control AC Drive

L1 Point-point Communication

Function
Name
Code
L1.00
Master and slave selection
L1.01
Send data selection of
master
L1.02
Point-point communication
enable
L1.03
Usage of data received by
slave
Unit's digit: Data usage of slave
Ten's digit: Whether to follow the master commands
L1.04
Gain of received data
L1.05
Zero offset of received data

L2 Encoder Setting

Function
Name
Code
L2.00
Encoder type
0: ABZ incremental Encoder
1: UVW incremental Encoder
L2.01
Encoder pulse per revolution
L2.02
A/B phase sequence of
ABC incremental Encoder
L2.03
Z pulse initial angle of ABZ
incremental Encoder
L2.04
Encoder installation angle
L2.05
UVW phase sequence of
UVW Encoder
L2.06
UVW Encoder angle offset
L2.07
poles of resolver
L2.08
Encoder wire-break fault
detection time
L2.09
Motor 2 Encoder type
Range
0~1
0~3
0~1
00~11
0: as torque reference
0: No
-9.99~10.00
-99.9~100.0
Range
0~4
2: Rotational resolver
3: Sine and cosine Encoder
1~65535
0~1
0.0~359.9
0.0~359.9
0~1
0.0~359.9
1~65535
0.0~10.0
0~4
83
-
-
Chapter 5 Parameter List Table
Default
Step
1
1
1
1
0
1
01
1
1: as frequency reference
1: Yes
1.00
0.01
0.0
0.1%
Default
Step
0
1
4: Wire-saving UVW Encoder
1024
1
0
1
0.0
0.1deg
0.0
0.1deg
0
1
0.0
0.1deg
1
1
0.0
0.1Sec
0
1
Description
0: Master
1: Slave
0: Torque reference
1: Running frequency
2: Setting frequency
3: Feedback frequency
0: Disabled
1: Enabled
Description
0: Positive
1: Negative
0: Positive
1: Negative
Same As L2.00

Advertisement

Table of Contents
loading