Allowed Dc Bus Continuous Power Without Auxiliary Components - Rexroth Indramat ECODRIVE03 Series Project Planning Manual

Drive controllers
Table of Contents

Advertisement

4-28
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200

Allowed DC bus continuous power without auxiliary components

1,8
1,6
1,4
1,2
1
0,8
0,6
0,4
0,2
0
200
customerservice@hyperdynesystems.com
DKC**.3-040-7 in "Single source supply":
250
300
Line input voltage U
Fig. 4-30:
Allowed DC bus continuous power for Single source supply
DKC**.3-040-7
DKC**.3-040-7 in "Group supply without DC bus
connection":
No increase in the allowed continuous power rating!
See page 4-23: "Arranging the Group supply without DC bus connection"
DKC**.3-040-7 in "Group supply with DC bus
connection":
Further DKC**.3-040-7 devices on the common DC-bus increase the
available continuous power. The increase can be seen in the diagram
"Fig. 4-30:
supply DKC**.3-040-7". It represents 80% of the value indicated.
DKC**.3-040-7 in "Central supply":
DKC**.3-040-7 as supply in "central supply" not allowed !
Note:
De nition of terms, see page 4-19: "Mains supply options".
ECODRIVE03 Drive Controllers
350
400
3*AC in V
N1
Allowed DC bus continuous power for Single source
|
(479) 422-0390
450
500

Hide quick links:

Advertisement

Table of Contents
loading