Rexroth Indramat ECODRIVE03 Series Project Planning Manual page 102

Drive controllers
Table of Contents

Advertisement

4-70
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
customerservice@hyperdynesystems.com
Voltage connection for brakes
Note:
The motor holding brake is not supplied by the controller.
Given one voltage source for brake and control voltage, use
parallel leads from the voltage source. Note the voltage range
for the motor holding brake according to the motor projection.
Risk of damage!
The maximum allowed current load of the terminals
for the voltage supply of the brake and the control
voltage supply must also be observed in the case of
CAUTION
a short circuit.
24V
to the central
ground
Fig. 4-104: Shared voltage source for brakes and control voltage supply
24V
Fig. 4-105: Looping through the brake supply
|
(479) 422-0390
ECODRIVE03 Drive Controllers
DKC
DKC
X1
X6
X6
X1
to additional
devices
X6
Ap5126f1.fh7
to additional
devices
X6
Ap5140f1.fh7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents