Rexroth Indramat ECODRIVE03 Series Project Planning Manual page 198

Drive controllers
Table of Contents

Advertisement

5-40
E
C
O
D
R
V I
E
0
3
D
K
voltage connection for brake:
Controlling the motor holding
Technical data
Motor holding brake:
customerservice@hyperdynesystems.com
C
* *
3 .
0 -
1
6
wire cross section:
wire
voltage resistance of single wire to ground
wire routing
max. inductance between 24 V source
and X6
Motor holding brake
The controller controls the holding brake.
brake:
Supply voltage, current consumption, linking, separating time, holding
torque, etc. see motor manual.
Basic connection of motor power, holding brake and
motor temperature monitoring
X5_M
XS1
X1
Fig. 5-66:
Connection of motor cable, holding brake and temperature monitor
for motors with connector box
Note:
The cable designations and all details on making cables are
outlined in the cable or motor document.
DKC
A1 A2 A3
XE1
X2
U
M
3
Temperature
dependent resistance
|
(479) 422-0390
E
C
O
D
R
V I
E
0
3
r D
v i
e
C
o
min. 1 mm ²
(e.g.: litz wires - H07)
parallel if possible
(equals about 2 x 75 m)
X6
0V
24V
Ext
24V
Ext
AC-Motor
Holding
brake
AP5387F1.FH7
n
r t
l o
e l
s r
> 750 V
(twisted)
100 µH