ECODRIVE03 Drive Controllers
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
CAUTION
If the DC bus rails supplied do not make a connection possible, then use
wire
short twisted wires to do so.
DC bus:
wire length:
wire cross section:
wire protection
Voltage resistance of individual wires
to ground
customerservice@hyperdynesystems.com
Damage possible if DC bus connections L+ and
L- are reversed!
Make sure polarity is correct.
4-63
max. 2 x 1 m
min. 10 mm ²,
not smaller than the cross
section of the mains supply
With a fuse in the mains
connections
> 750 V