Rexroth Indramat ECODRIVE03 Series Project Planning Manual page 138

Drive controllers
Table of Contents

Advertisement

4-106
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
Transmitter power
Switch
position
position
S20/2
OFF
ON
OFF
ON
customerservice@hyperdynesystems.com
The transmitter power is set with the switches S20/2 and S20/3.
The following table demonstrates the relationship between switch position
and transmitter power.
Switch
Transmission
power at
optimum high
S20/3
level in
dBm
OFF
-7
OFF
-4,5
ON
-1
ON
0
Fig. 4-179: Relationship between switch position S20/2, S20/3 and the data rate
(*1): The data for the maximum lengths of the ber optic cable only apply
if the following preconditions have been met:
Rexroth Indramat ber optic cables IKO 982, IKO985 or IKO 001 are
used
Connection without separation. If couplings are used, the maximum
length for plastic ber optic cables is reduced by about 10 meter, 100
meters for glass ber optic cables.
Fiber optic cables
Drives with a SERCOS interface are connected to higher-level controls
with a ber optic cable.
The ber optic cables (cables, connectors or complete leads) must be
ordered separately.
For more information, see "Fiber optic cables
"LWL-Handling" (DOK-CONNEC-CABLE*LWL-AWxx-EN-P).
"LWL-Handling" discusses:
Fiber optics in general
Basic plans for optical transmission systems
Routing guidelines for ber optic cables
Attenuation readings of standard LWL cables
Available ber optic-FSMA plug-in connectors and ber optic cables
Guidelines on making an FSMA connector
Tools for making ber optic cables
Use the following illustration to nd out which ber optic cable to order.
ECODRIVE03 Drive Controllers
Transmission
power at
optimum high
level in
µW
200
350
800
1000
|
(479) 422-0390
Maximum
Maximum
length with
length with
plastic
glass
ber optic
ber optic
(*1)
(*1)
0...15 m
--
15...25 m
--
25...35 m
--
35...50 m
0...500 m