ECODRIVE03 Drive Controllers
Controlling with the stepper
motor interface:
Control with di erential signals:
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
1: Quadrature-signals
SM 1
SM 2
2: Seperate signals for forward/ backward count
SM 1
SM 2
3: Count and direction signals
SM 1
SM 2
Fig. 4-174: Stepper motor interface types of control
Logic 1 is detected with a positive voltage di erence of SM+ to SM-.
Logic 0 is detected with a negative voltage di erence of SM+ to SM-.
To increase noise immunity the amplitude of the voltage di erence
should equal at least 3.0 volts. The greater the voltage di erence, the
better the noise immunity.
customerservice@hyperdynesystems.com
turning ccw
t1
t1
t1 1,4 µs
turning ccw
t2
t2 5,6 µs
u t
n r
n i
g
c c
w
t
t3
L
tL 2,8 µs
t3 5,6 µs
|
(479) 422-0390
4-103
turning cw
turning cw
u t
n r
n i
g
c
w