Ambient And Operating Conditions - Rexroth Indramat ECODRIVE03 Series Project Planning Manual

Drive controllers
Table of Contents

Advertisement

4-4
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200

Ambient and operating conditions

Ambient temperature and
installation altitude
customerservice@hyperdynesystems.com
Note:
ECODRIVE03 drive control devices and its auxiliary
components are designed for control cabinet mounting.
Selection lists are speci ed for each motor/drive combination.
The selection lists apply to motors and drives within the speci ed ambient
and operating conditions (see "Fig. 4-5: Ambient
conditions").
Di ering conditions reduce the performance speci cations
of the drive:
allowed DC bus continuous output
continuous bleeder output
continuous current
of the motor:
output
continuous torque at standstill
S1 continuous torque
Short-time operating torque M
according to the diagrams (see "Fig. 4-4:
value dependent on ambient temperature and installation altitude"). If
deviating ambient temperatures and higher installation altitudes occur
simultaneously, both utilization factors must be multiplied. The installation
altitude must only be taken into account once. Deviating ambient
temperatures must be taken into account separately for motor and drive
controller.
Load capacity dependent on
ambient temperature
1
0,8
0,6
40
45
Ambient temperature in °C
Fig. 4-4:
Degree of utilization as a value dependent on ambient temperature
and installation altitude
|
(479) 422-0390
ECODRIVE03 Drive Controllers
KB
Degree of utilization as a
Load capacity dependent on
installation elevation
1
0,8
0,6
500
50
55
0
Installation elevation in meters
and
operating
1000
1500 2000
above sea level
DG5025F1.FH7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents