Electric Data Of The Individual Dkc**.3-016 Components - Rexroth Indramat ECODRIVE03 Series Project Planning Manual

Drive controllers
Table of Contents

Advertisement

5-4
E
C
O
D
R
V I
E
0
3
D
K
C

Electric Data of the Individual DKC**.3-016 Components

D
s e
g i
n
t a
o i
n
O
p
r e
t a
n i
g
m
o
d
e
t a
h t
e
m
M
i a
s n
n i
p
t u
o v
a t l
g
e
M
i a
s n
f
e r
q
u
e
n
y c
R
o
a t
y r
e i f
d l
C
o
n
n
c e
e t
d
l
a o
d
Nominal charging current
(dependent on mains input voltage)
S
f o
s - t
a t
t r
e r
i s
t s
r o
Continuous power soft-start resistor
Switching frequency (selectable)
Type current = peak current 1
Peak current 2 for f
= 4 kHz
S
Peak current 2 for f
= 8 kHz
S
Continuous current 1 for f
Continuous current 2 for f
Continuous current 1 for f
Continuous current 2 for f
Max. output frequency at f
Max. output frequency at f
Device power dissipation without
internal continuous bleeder power
for I
CONT2
Peak bleeder power DKC
when U
= 850 V
ZW
for permissible load cycle
Continuous bleeder power DKC
when T
< 45 °C
a
under max. temperature range
with distance
Max. energy dissipation
M
a
. x
D
C
b
s u
c
a h
g r
e
Internal DC bus dynamic brake
(ZKS)
R
s e
s i
o t
f r
r o
Z
K
S
Storable energy of the DC bus
capacitors
Nominal DC bus capacitance DKC
DC bus voltage
(dependent on mains input voltage)
DC bus continuous power
(dependent on mains input voltage)
max. DC bus continuous power
for a single source supply where
U
= 3 x AC 400 V, when
N1
Ta < 45 °C
customerservice@hyperdynesystems.com
* *
3 .
0 -
1
6
Mains connections, Power section DKC**.3-016-FW
S
y
m
b
l o
i a
s n
U
N1
f
N1
S
N1
R
Softstart
P
Softstart
f
S
I
PEAK1
I
PEAK2(4kHz)
I
PEAK2(8kHz)
= 4 kHz
I
S
CONT1(4kHz)
= 4 kHz
I
S
CONT2(4kHz)
= 8 kHz
I
S
CONT1(8kHz)
= 8 kHz
I
S
CONT2(8kHz)
=4 kHz
f
S
out
=8 kHz
f
S
out
P
V
P
BS
P
BD
d
W
R,MAX
W
MAX
R
ZKS
W
ZW
C
ZW
U
ZW
P
ZWD
P
ZWD
U
n
t i
s
n i
g
e l
p
V
1 x AC
Hz
c
o l
k c
kVA
see page 11-1: "Mains Connections"
Ohm
kW
kHz
A
A
A
A
A
A
A
Hz
Hz
W
(see page 12-1: "Power dissipation")
k
W
kW
K
mm
k
W
s
k
W
s
O
h
m
Ws
see diagrams page 5-9: "Storable energy in the
m
F
V
see diagrams page 5-12 "Allowed DC bus
k
W
|
(479) 422-0390
E
C
O
D
R
V I
E
0
3
r D
v i
e
C
o
DKC**.3-016-7-FW
a h
e s
h t
e r
e
p
a h
3 x AC
(200 ... 480) ± 10%
)
(50 ... 60
± 2
i w
e s
r o
c
o
u
t n
r e
c -
o l
k c
i w
e s
1.2 ... 2.8
240
2)
0.05
4 or 8
1)
16
1)
6
1)
5
1)
4
1)
6
1)
2.8
1)
5
400
800
8
0
2
7 .
0.29 s on, 20 s o
0.05
40 K
80 (see page 12-7)
1
0 .
1
0 .
not present
n
t o
p
e r
e s
t n
bus"
0
1 .
3
5
±
2
0
%
D
C
3
0
0
. . .
8
0
0
continuous power"
0
5 .
n
r t
l o
e l
s r
e s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents