Rexroth Indramat ECODRIVE03 Series Project Planning Manual page 64

Drive controllers
Table of Contents

Advertisement

4-32
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
14,00
12,00
10,00
8,00
6,00
4,00
2,00
0,00
200
customerservice@hyperdynesystems.com
DKC**.3-100-7 with CZM01.3 in "Single source supply":
250
300
Line input voltage U
Fig. 4-33:
Allowed DC bus continuous power for Single source supply
DKC**.3-100-7 with CZM01.3
DKC**.3-100-7 with CZM01.3 in "Group supply without
DC bus connection":
No increase in the allowed continuous power!
See page 4-23: "Arranging the Group supply without DC bus connection"
DKC**.3-100-7 with CZM01.3 in "Group supply with DC
bus connection":
See "DKC**.3-100-7 with CZM01.3 in "Central supply":"
DKC**.3-100-7 with CZM01.3 in "Central supply":
Further DKC**.3-***-7 devices on the common DC-bus increase the sum
of the available continuous power. The increase can be seen in the
diagram "DKC**.3-***-7 in Single source supply" of each particular device.
The sum of the allowed DC bus continuous power is limited to the
performance speci cations of the DKC**.3-100-7 with CZM 01.3 in Single
source supply.
Note:
De nition of terms, see page 4-19: "Mains supply options".
|
ECODRIVE03 Drive Controllers
350
400
3*AC in V
N1
(479) 422-0390
450
500