Maintenance 3. Covers

3.1 Arm #1 Cover

Remove the bolts and then remove the Arm #1 Cover.
Tool : Hexagonal wrench (width across flats: 3 mm)
Button bolt
Tightening torque : 1.4 N·m (0.14 kg·m)
For cleanroom-model:
A gasket (R13B031270) is attached.
Removal
Remove the gasket with the cover.
Installation
Attach the gasket between the cover and
manipulator.
NOTE
You can't reuse the gasket. Be sure to use a new gasket.
For protection-model:
Liquid gasket (R13B031201) is applied.
Removal
Remove caked-on liquid gasket residue with a
scraper or similar tool.
Installation
Apply liquid gasket on the contact surfaces of the cover and manipulator.
NOTE
Wipe off any excess liquid gasket with a wiping cloth treated with alcohol.