Maintenance 9. Cable Unit
(12) Mount the supporting plate inside the Arm #1.
(13) Secure the supporting plate and saddle.
(14) Connect the connector to the lead line.
(15) Mount the rubber plate and saddle to the spring (some winds from the end) of the
(16) Secure the saddle to the Arm #2.
170
Remove the backup battery.
Connector: For Joint #2 (L), For Joint #3 (U)
lead line.
Hexagon socket head cap bolt
: 2-M4×6
(with disc spring 2H-4, M4 washer)
Tightening torque
: 2.8 N·m (0.29 kgf·m)