Piper Malibu PA-46-310P Pilot Operating Handbook page 82

Table of Contents

Advertisement

PIPER AIRCRAFT CORPORATION
PA-46-310P, MALIBU
SECTION 3
EMERG PROCEDURES
INADVERTENT ICING ENCOUNTER OR FLIGHT IN SNOW
Pitot heat. ......................................................................................................... ON
Cabin heat ................................................................................................. full ON
Windshield defrost. .......................................................................................... ON
Vent/Defog Fan ............................................................................................... ON
Change heading and/or altitude to exit icing conditions or snow.
Induction air ............................................................................................. monitor,
ALTERNATE ifrequired
HYDRAULIC SYSTEM MALFUNCTION (serial numbers 46-8508048
through 46-8608046, unless Piper Kit No. 765 197 is installed).
HYD PUMP annunciator light illuminates continuously. or cycles on and
off rapidly.
HYD PUMP circuit breaker ............................................................................ pull
Land as soon as possible and investigate the cause.
' HYDRAULIC SYSTEM MALFUNCTION (serial numbers 46-8608047
~
and up, and aircraft with Piper Kit No. 765 178V, 765 179V or 765 197
installed).
HYD PUMP amber annunciator light illuminates continuously.
HYD PUMP circuit breaker ............................................................ pull and reset
Verify normal hydraulic system operation.
If HYD PUMP annunciator light illuminates second time:
HYO PUMP circuit breaker ............................................................................ pull
Land as soon as possible and investigate cause.
FLAP SYSTEM MALFUNCTION (serial numbers 46-8608001 and up,
and aircraft with Piper Kit No. 765 523 installed).
FLAPS annunciator light illuminated.
FLAP WARN/RESET circuit breaker ............................................. Pull and reset
Verify normal flap operation.
If FLAPS annunciator light remains illuminated:
FLAP MOTOR circuit breaker ....................................................................... Pull
Land as soon as possible and investigate the cause.