Piper Malibu PA-46-310P Pilot Operating Handbook page 261

Table of Contents

Advertisement

SECTION 7
DESCR/OPERATION
PIPER AIRCRAFT CORPORATION
PA-46-310P, MALIBU
extension control, place the landing gear selector in the DOWN position
and pull the HYO PUMP circuit breaker to keep the pump from operating
continuously. If the EMERGENCY GEAR control has been pulled out to
lower the gear by gravity due to a gear system malfunction, leave it in its
extended position until the airplane has been put on jacks to check the proper(
J
function of the landing gear hydraulic and electrical systems. See the Service~
Manual for proper landing gear system check-out procedures. If the
airplane is being used for training purposes or a pilot check-out flight and
the emergency gear extension knob has been pulled out, it may be pushed in
again when desired if there has not been any apparent malfunction of the
landing gear system.
- ~
FUEL SELECTOR
O F F ~
L - . :
® ~ © L N R
I
~
g
R
T
E T
@
@
EMERGENCYGEARFXTENSIDN
PULL TORELEASE,SFF AFM
c,EFORE RE:·ElloGAGfl'wlENT
-----.... e
LANDING GEAR SELECTOR
Figure 7-7
The hydraulic reservoir for landing gear operation is an integral part of
the hydraulic pump. Access to the combination pump and reservoir is
through a panel in the aft baggage compartment. For filling instructions, see
the Service Manual.
NOTE
Flaps are inoperative when HYO PUMP
circuit breaker is pulled. (Serial numbers 46-
840800 l thru 46-8508109).
REPORT: VB-1200
7-12
ISSUED: JANUARY 11. 1984
REVISED: JANUARY 15, 1986