Piper Malibu PA-46-310P Pilot Operating Handbook page 499

Table of Contents

Advertisement

MALIBU POWER & PROPELLER INT'L, LLC
Page 5 of7
4600 Lake Road
Minneapolis, MN 55422
AFM SUPPLEMENT for PA-46-31 OP
2.0
LIMITATIONS (Cont'd)
2.11
POWER PLANT INSTRlJl\,ffiNT MARKINGS
a) Tachometer
Green Arc (Normal Operating)
600-2600 RPM
Red Line (Maximum)
2600RPM
b)
Manifold Pressure
Green Arc (Normal Operating Range)
10 to 35.5 in. Hg
Red Line (Takeoff Power)
35.5
in.
Hg
c)
Oil Temperature
Green Arc (Normal Cruise Range)
170° to 200° F
Red Line (Maximum)
240°F
d)
Oil Pressure
Green Arc (Normal Cruise Range)
30 PSI to 60 PSI
Yellow Arc (Caution Range) (Idle)
10 PSI to 30 PSI
Yellow Arc (Caution Range) (Start and Warm Up)
60 PSI to 100 PSI
Red Line (Minimum)
lOPSI
Red Line (Maximum)
IOOPSI
e) Fuel Flow
Green Arc (Nonna) Operating Range)
6 to 40 gaJ/hr.
Red Line (Maximum)
40 gal/hr.
t) Turbine Inlet Temperatures
Green Arc (Norma] Operating Range)
1200° F to 1750° F
Red Line (Maximum)
1750°F
g) Cylinder Head Temperatures
Green Arc (Normal Operating Range)
240° F to 420° F
Red Line (Maximum)
460°F
h)
Vacuum Pressure
Green Arc (Normal Operating Range)
4.8 to 5.2 in. Hg
Red Line (Minimum)
4.8 in. Hg
Red Line (Maximum)
5.2 in. Hg
FAA Approved:---------
Date:
F£B
O 6 2003
Charles L. Smalley
Manager, Systems
&
Flight Test Branch
Chicago Aircraft Certification Office
2300 E Devon Ave., Des Plains, IL 60018