[Temperature parameters]
Parameter
Temp unit
Temperature unit
Temp damp
Temperature damping
8.5 Pulse Output Function
By using the pulse output function, the measurement values can be output from the PULSE terminal.
〈CAUTION〉
By changing the pulse output assign, full-scale flowrate or full-scale
frequency, the total counter and the total flowrate value (Counter / Totalizer)
will be reset.
Parameter
Assign
Pulse output assignment
Mode
Output valid / invalid setting
Full-scale frequency of pulse output
※This is not the higher limit of output
Freq Factor
Rate Factor
Full-scale flowrate of pulse output
Low cut of pulse output.
Setting will be done by certain
Lowcut
percentage value to the Rate Factor
and pulse output will be cut off if
below set range.
Pulse output status upon
Error output
occurrence of an error
Pulse output frequency during
Pulse upscale freq
upscaling
Descriptions
Descriptions
frequency. Depending on the
flowrate, output will be generated
even if frequency exceeds the set
value.
Setting range
Refer to the list of setting units.
0 to 00 [sec]
Setting range
Mass Flow
Volume Flow
Normal (valid) /
Stop (invalid)
0. to 0000 [Hz]
―
0 to 0 [%]
Zero:Stop output
Hold:Output retention
Upscale:Pulse upscale freq
0. to 000 [Hz]
L-770HP--E
Standard value
℃
. sec
Standard value
Mass Flow
Normal
000 Hz
According to the
specification
0 %
Zero
000Hz