Nera WILINK I System Manual page 91

Modular
Table of Contents

Advertisement

Chapter 4 - Operation and Administration
C
Any subnet reachable via the default Gateway of the Data port (if Data Port
Gateway is defined).
If remote management is enabled for both the Data Port and the Management
port, then the unit can be managed by any PC on any of the following subnets
(provided the PC is defined as an Authorized Manager):
A
The local subnet of the Management port (defined by the Management Port IP
Address and Management Port Subnet Mask parameters).
B
The local subnet of the Data port (defined by the Data Port IP Address and
Data Port Subnet Mask parameters).
C
Any subnet reachable via the default Gateway of the Data port (if Data Port
Gateway is defined).
D
The Static Route subnet (defined by the Management Port Dest Subnet and
Management Port Dest Subnet Mask parameters) reachable via the Gateway
of the Management port.
NOTE
To prevent the undesired situation where remote management traffic is unintentionally disabled in
both the Management and Data ports, the Data Port Management Traffic Enable/Disable parameter
will be automatically forced to Enabled upon disabling the Management Port Management Traffic,
and vice versa.
4.5.3.2
Data Port Parameters
These parameters define the IP and Ethernet parameters for the Data (DATA) port
connecting the base station to the backbone.
4.5.3.2.1 Data Port IP Address
The IP address of the Data port.
The default is 1.1.1.3.
4.5.3.2.2 Data Port Subnet Mask
The subnet mask of the Data port.
The default is 255.255.255.0.
NOTE
The local subnet of the Data port (defined by the Data Port IP Address and Data Port Subnet Mask
parameters), must differ from the local subnet of the Management port (defined by the
Management Port IP Address and Management Port Subnet Mask parameters) and from the
subnet that is used as the Static Route for remote management via the Management port (defined
by the Management Port Dest Subnet and Management Port Dest Subnet Mask parameters).
4.5.3.2.3 Data Port Gateway
The IP address of the default Gateway for the Data port.
The default is 0.0.0.0.
80