Chapter 4 - Operation and Administration
operation was executed for this file name), the only actual operation to take place
will be to swap the Main and Shadow versions. If it is already defined as the Main
version, no action will take place.
4.8.4.3
Configuration
The AU Configuration menu enables viewing and updating the AU's parameters.
It is important to note that changes to some parameters take effect only after
reset. For these parameters, the applicable Show menus display the Current as
well as the Configured value.
The Configuration menu includes the following options:
MAC
Phy
Multi Channel
Multirate
Voice Parameters
4.8.4.3.1 MAC Parameters
The MAC menu enables viewing/updating the following parameters:
4.8.4.3.1.1 ID Parameters
The Operator ID, Cell ID and Sector ID constitute together the Base Station ID,
which is the unique identifier of the AU. An SU can be authenticated by the AU
only if its defined parameters match the Base Station ID configured for the AU.
The Operator ID and Cell ID are defined for the Base Station (see Section 4.4.2.4)
and are used by all AUs in the Base Station. In the AU's MAC Parameters menu
they are available only in the Show option.
The Sector ID parameter consists of three digits in the range of 0 to 255.
The default Sector ID is 206.
Changes in Sector ID are applied only after reset.
4.8.4.3.1.2 ARQ Enable/Disable
The ARQ Enable/Disable parameter controls whether to use an ARQ algorithm
for detecting errors and requesting retransmissions of applicable unicast
messages (applicable only for Best Effort and Non Real Time services).
The default is Disable.