4.9.6.3.6.2 Update
Select the Update option to configure the Ethernet Port Configuration
parameter. The available options are 10 Half, 10 Full, 100 Half, 100 Full and
Auto Negotiation.
The default is Auto Negotiation.
4.9.6.3.7 Installer Password
The Installer Password option enables viewing the current Installer Password and
configuring a new password. The Installer Password is used for accessing the
SU's Monitor (Installer) program locally, using Telnet via the SU's Ethernet port.
The Installer Password consists of a string of up to 20 printable characters, case
sensitive.
The default Installer Password is installer.
4.9.6.3.8 Bridging Parameters
The Bridging Parameters menu enables setting a limit on the maximum number
of Ethernet devices behind the SU and configuring the aging time for devices in
the SU's bridging table. The Bridging parameters are:
4.9.6.3.8.1 Enable/Disable Limit on Number of Supported Devices
If the Enable/Disable Limit on Number of Supported Devices parameter is set to
Disable, the maximum number of supported devices is 512.
The default is Disable.
4.9.6.3.8.2 Maximum Number of Supported Devices
This parameter is applicable only when the Enable/Disable Limit on Number of
Supported Devices parameter is set to Enable.
The available range is from 1 to 512 devices.
The default is 512.
4.9.6.3.8.3 Bridge Aging Time
The Bridge Aging Time sets the aging time for all addresses in the SU's
Forwarding Data Base.
The available values are from 1 to 1440 minutes.
The default is 3 minutes.