Table 1-14: Mechanical Specifications, Base Station Equipment; Table 1-15: Electrical Specifications, Base Station Equipment - Nera WILINK I System Manual

Modular
Table of Contents

Advertisement

1.5.9
Physical and Electrical
1.5.9.1
Mechanical
Unit
BST-SH
PIU
PSU
NPU
AU-IDU
AU-ODU
AVU
* 1U=44.45 mm (1.75"), 1HP=5.08 mm (0.2")
1.5.9.2
Electrical
Unit
Power Source
Full Base station, including
1 ODU per AU
Full Base station, including
2 ODUs per AU
Full Chassis (excluding
ODUs)
Base station with 4 AUs,
including 1 ODU per AU
Base station with 4 AUs,
including 2 ODUs per AU
Chassis with 4 AUs
(excluding ODUs)
PIU
WILINK I MODULAR BASE STATION SYSTEM MANUAL

Table 1-14: Mechanical Specifications, Base Station Equipment

Dimensions (cm)
8U ETSI type shelf, 8U x 43.19 x 24
3U x 5HP x 16
3U x 8HP x 16
6U x 7HP x 16
6U x 7HP x 16.
31.5 x 8.8 x 15.7
2U x 84HP x 16

Table 1-15: Electrical Specifications, Base Station Equipment

Details
-40.5 to -60 VDC
640W maximum for a fully equipped base station, including 6 ODUs
(1 NPU, 6 AUs with 1 ODU per AU, 1+1 PIUs, 2+1 PSUs)
868W maximum for a fully equipped base station, including 12 ODUs
(1 NPU, 6 AUs with 2 ODUs per AU, 1+1 PIUs, 2+1 PSUs)
412W maximum for a fully equipped chassis, excluding ODUs
(1 NPU, 6 AU-IDUs, 1+1 PIUs, 2+1 PSUs)
470W maximum for a chassis with 4 AUs, including 4 ODUs (1 NPU,
4 AUs with 1 ODU per AU, 1+1 PIUs, 2+1 PSUs)
621W maximum for a chassis with 4 AUs, including 8 ODUs (1 NPU,
4 AUs with 2 ODUs per AU, 1+1 PIUs, 2+1 PSUs)
317W maximum for a chassis with 4 AUs, excluding ODUs
(1 NPU, 4 AU-IDUs, 1+1 PIUs, 2+1 PSUs)
16W maximum (active PIU)
Specifications
Weight (kg)
6.9 (excluding AVU)
0.35
0.7
0.7
0.6
2.9
1.7
19