4.10.4.7.6 Packet Size (CG QoS Type)
The Packet Size parameter defines the amount of data in bytes that is expected
for each grant.
The range is from 64 to 1550 (bytes).
4.10.4.7.7 Sample Interval (CG QoS Type)
The Sample Interval parameter defines the time in milliseconds between two
successive grants (inter arrival time).
The range is from 5 to 100 (milliseconds).
4.10.4.8
Filtering Rules
The Filtering Rules menu enables defining L2 Filtering Rules and L3/L4 Filtering
Rules.
4.10.4.8.1 L2 Filtering Rules
An L2 (Layer 2) Filtering Rule includes the MAC Address and Ethertype. A range
of MAC Addresses can be defined for either the Source or Destination MAC
Address field. It is possible to define "Any" for either the MAC Address or
Ethertype field (but not for both fields).
The L2 Filtering Rules menu enables defining new L2 Filtering Rule, viewing
details of previously defined L2 Filtering Rules and removing L2 Filtering Rules
from the database. It is not possible to edit the parameters of an existing L2
Filtering Rule. The database can hold up to 255 L2 Filtering Rules.
The configurable L2 Filtering Rule parameters are:
4.10.4.8.1.1 Rule Name
The name of the L2 Rule. The L2 Rule Name is a string of 1 to 32 printable
characters.
4.10.4.8.1.2 MAC Address
The base MAC Address that is used together with the MAC Address Mask to
define a range of MAC addresses. A string of 6 octets (where each octet is
represented by two hexadecimal numbers) separated by dashes ("-"). An empty
entry means "Any". An "Any" MAC Address means that the filter is defined only
by the Ethertype field.
4.10.4.8.1.3 MAC Address Mask
The mask that is used together with the MAC Address to define a range of MAC
addresses. A string of 6 octets (where each octet is represented by two
hexadecimal numbers) separated by dashes ("-"). In a binary representation the
string must comprise a series of contiguous binary '1's starting from the MSB,
followed by a series of contiguous binary '0's (if the range includes more than a
152