EAS20615
P1602
EAS33095
TROUBLESHOOTING
Item
Malfunction in ECU internal circuit (malfunction of ECU power cut-off function).
Fail-safe system
• Able/Unable to start engine
• Able/Unable to drive vehicle
Procedure
1. Installed condition of battery leads.
• Check the installed condition of the battery and battery leads (loose bolts).
Is check result OK?
YES
 Go to step 2.
NO
a. Reinstall or replace the battery leads.
b. Push the ON/start switch, and then check the condition of the DTC using the malfunction mode
of the YDT.
Is it in the "Recovered" condition?
YES
 Go to step 6, and complete the service.
NO
 Go to step 2.
2. Connection of starter relay coupler.
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is the coupler condition normal?
YES
 Go to step 3.
NO
a. Connect the coupler securely or replace the wire harness.
b. Push the ON/start switch, and then check the condition of the DTC using the malfunction mode
of the YDT.
Is it in the "Recovered" condition?
YES
 Go to step 6, and complete the service.
NO
 Go to step 3.