EAS20585
P0480
EAS33065
TROUBLESHOOTING
Item
Radiator fan motor relay: open or short circuit detected.
Fail-safe system
• Able to start engine
• Able to drive vehicle
Procedure
1. Connection of radiator fan motor relay coupler.
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is the coupler condition normal?
YES
Go to step 2.
NO
a. Connect the coupler securely or replace the wire harness.
b. Push the ON/start switch, and then check the condition of the DTC using the malfunction mode
of the YDT.
Is it in the "Recovered" condition?
YES
Go to step 6, and complete the service.
NO
Go to step 2.
2. Connection of ECU coupler.
• Check the locking condition of the coupler.
• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is the coupler condition normal?
YES
Go to step 3.
NO
a. Connect the coupler securely or replace the wire harness.
b. Push the ON/start switch, and then check the condition of the DTC using the malfunction mode
of the YDT.
Is it in the "Recovered" condition?
YES
Go to step 6, and complete the service.
NO
Go to step 3.
9-112
P0480