Diagnostics and troubleshooting

For the PROFINET, there are two different options for diagnosis.
Event-related diagnostics
PROFINET transmits events within an automation process as alarms that must be
acknowledged by the application process.
The following events are possible:
• Process alarms: Events that originate from the process and are reported to the control.
• Diagnostic alarms: Events that indicate the malfunctioning of an IO device.
• Maintenance alarms: Transmission of information to avoid the failure of a device
through preventative maintenance work.
• Manufacturer-specific diagnostics
To identify the alarms uniquely, they are always reported via a slot/subslot. The user can
prioritize diagnostic and process alarms differently.
State-related diagnostics
In addition, all alarms are entered into the diagnostics buffer. If required, this buffer can be
read by a primary instance via acyclic read services.
A further option to report malfunctioning or status changes in a field device to a plant control
is to enter low-priority diagnostic or status messages into the diagnostic buffer only instead
of actively reporting them to the primary control.
This option can also be used for preventative maintenance or for low-priority warnings, for
example.
The AMS
348i
well as the state-related diagnostics for preventative maintenance and the signaling of low-
prioritized events or warnings.
The following alarms and diagnostics messages are supported:
Diagnostics
Parameter error
Configuration error
1)
n = module number
2)
Only diagnostics or process alarms actually trigger the transmission of an alarm. All other
types (preventative maintenance and status messages) only lead to an entry into the
diagnostics buffer and are thus part of the state-based diagnostics.
Table 10.1:
Leuze electronic
uses both the event-related diagnostics for high-prioritized events/errors as
Description
AMS 348
category
Error in the configuration
Error
of a module.
Error in the configuration
Error
of a module.
AMS 348 alarm and diagnostics messages
Diagnostics and troubleshooting
API/
Slot/
Subslot
Diagnostics
1)
0/n
/0
alarm
Diagnostics
0/n/0
alarm
AMS
348i
Type
Coming/
going
Coming only
2)
Coming only
Remark
92