Connecting The Voltage Supply; Display; Ams 348 On The Profinet - Leuze electronic AMS 348i Manual

Optical laser measurement system
Table of Contents

Advertisement

Fast commissioning / operating principle
3.2

Connecting the voltage supply

The laser measurement system is connected using M 12 connectors. The voltage supply is
connected via the PWR M 12 connection (18 ... 30 V DC). 2 freely programmable switching
inputs/outputs for individual adaptation to the respective application are also available here.
Detailed information can be found in chapter 7.
3.3

Display

Once the laser measurement system is supplied with voltage, the device status as well as
the measured position values can be read on the display. The display automatically switches
to the display of the measurement values.
Use the up/down buttons
of data and parameters.
Detailed information can be found in chapter 8.
3.4
AMS
348i
Install the GSDML file associated with the AMS
control. Activate the desired modules (at least one module).
The network address for PROFINET is assigned via the PROFINET Manager.
Standalone operation in PROFINET
During standalone operation of the AMS 348i, the PROFINET network is connected to
BUS IN. BUS OUT requires no terminating resistor.
Network operation in PROFINET
In network mode the AMS
participants can be connected to the integrated switch of the AMS
connection.
Commissioning of the AMS
The procedures described below are for the configuration of an AMS
Simatic S7 PLC.
• Switching on the supply voltage. 
The AMS
• Installation of the corresponding GSD file in the Simatic Hardware Manager.
• Projection of the PROFINET network including the AMS
the IP addresses, sub-network mask and definition of a device name assigned to the
IP address.
• Download of the project to the connected Siemens control.
Further information regarding the individual commissioning steps is provided in see chapter
9.8.4 "Configuration steps for a Siemens Simatic S7 control".
Detailed information can be found in chapter 9.
11
on the PROFINET
348i
is connected to PROFINET via BUS IN. Further PROFINET
348i
348i
displays the "Status and measurement values" main menu.
to the left of the display to read and change a wide range
348i
AMS
348i
in the PROFINET Manager of your
348i
via the BUS OUT
348i
with a Siemens
348i
GSD file. Definition of
Leuze electronic

Hide quick links:

Advertisement

Table of Contents
loading