PROFINET interface
Notice!
The current GSD file for the AMS
www.leuze.de -> Download -> identify -> Optical distance measuring and
positioning -> GSD files AMS 304i
The participant (here AMS 348i) is configured via the GSD file with a user-specific
configuration tool such as the Siemens Simatic Manager.
The exchange of data and the configuration of parameters is organized by means of the
GSD file.
All the parameters of the AMS
depending on the application. The user activates only the modules from the GSD file whose
parameters should be changed or whose input/output data are to be read.
For this purpose, the corresponding module from the GSD file is activated and configured
or prepared for control and reading of inputs and outputs.
All parameters and accesses to the AMS
the configuration is written to the AMS according to predefined control criteria.
Notice!
Parameters can be changed via the display on the AMS
parameter enabling is activated on the display, the AMS
PROFINET. All the parameters set via the GSD file initially remain active in the AMS 348i.
Parameter changes can now be made via the display for test purposes. If parameter enabling
is deactivated via the display, only the parameters entered in the PROFINET modules and
the PROFINET default settings are in effect.
Parameter changes made via the display are no longer in effect on the PROFINET!
Attention!
The laser measurement system does not permanently store parameters changed via the
PROFINET. Following power OFF/ON the currently configured parameters are downloaded
by the PROFINET master. If the PROFINET master is no longer available after power OFF/
ON, the default parameters are valid.
Notice!
All input and output modules described in this documentation are described from the
controller's perspective:
Described inputs (I) are inputs of the control.
Described outputs (O) are outputs of the control.
Described parameters (P) are parameters of the GSD file in the control.
63
348i
can be found on our homepage under:
348i
are preset default values. These can be altered,
348i
are thus stored in the control. If necessary,
AMS
348i
348i
for test purposes. As soon as
348i
is deactivated on the