Profinet - General Information On Wiring; Profinet - Cable Lengths And Shielding - Leuze electronic AMS 348i Manual

Optical laser measurement system
Table of Contents

Advertisement

9.5
PROFINET – General information on wiring
A Cat. 5 Ethernet cable should be used for wiring.
For the connection technology transition from M12 to RJ45, a "KDS ET M12 /
RJ 45 W - 4P" adapter is available that lets you connect standard network cables.
If no standard network cables are to be used (e.g. due to lacking IP... protection class), you
can use the "KB ET - ... - SA" ready-made cable on the AMS 348i, see table 11.4.5 "Acces-
sory ready-made cables for PROFINET" on page 100.
The individual AMS
SSA" cable, see table 11.4.5 "Accessory ready-made cables for PROFINET" on page 100.
For unavailable cable lengths, you can configure your cables yourself. For this purpose,
Leuze electronic offers a D-coded M 12 round plug connector for Bus IN and Bus Out, see
table 11.4.3 "Accessory M 12 connector" on page 98.
9.6
PROFINET – Cable lengths and shielding
 Observe the following maximum cable lengths and shielding types:
Connection
AMS – host
Network from the
first AMS to the
last AMS
Table 9.2:
Leuze electronic
348i
devices in a linear topology are connected with the "KB ET - ... -
Interface
PROFINET-RT
100 m
The maximum segment length
must not exceed 100 m for
PROFINET-RT
100Base-TX Twisted Pair
(min. Cat. 5)
Cable lengths and shielding
AMS
Max. cable length
348i
PROFINET interface
Shielding
Absolutely required
Absolutely required
52