Leuze electronic AMS 348i Manual page 76

Optical laser measurement system
Table of Contents

Advertisement

PROFINET interface
9.9.3.20 Module 5: I/O 2 Input/Output
PROFINET module identifier
Module-ID
Submodule-ID
Description
The module defines the mode of operation of the digital input/output I/O 2.
Parameters
Parameter
Description
The parameter defines whether I/O 2
a
functions as an input or as an output.
Function
The parameter defines the level of the
b
output when the "output" event is
received. If I/O 2 is configured as an
Activation
input, the response is edge-controlled.
The parameter defines which event trig-
c
gers activation of the output. The individ-
ual functions are OR-linked to one
another.
Position limit value 1
If the position value lies outside of con-
figured limit range 1, the output is set.
Position limit value 2
If the position value lies outside of con-
figured limit range 2, the output is set.
Velocity limit value
If the velocity value lies outside of the
configured values, the output is set.
Monitoring from modules 11 to 15 is OR-
linked.
Output
Intensity (ATT)
If the intensity of the received signal is
less than the warning threshold, the
output is set.
Temperature (TMP)
If the internal device temperature
exceeds the set limit value, the output is
set.
Laser (LSR)
Laser prefailure message.
Plausibility (PLB)
If implausible measurement values are
diagnosed, the output is set.
73
1005
1
Rel.
Data
Value
addr.
type
0: Input
0.0
Bit
1: Output
0: Low 
0.1
Bit
1: High 
0 = OFF
1.0
Bit
1 = ON
0 = OFF
1.1
Bit
1 = ON
0 = OFF
1.2
Bit
1 = ON
0 = OFF
1.3
Bit
1 = ON
0 = OFF
1.4
Bit
1 = ON
0 = OFF
1.5
Bit
1 = ON
0 = OFF
1.6
Bit
1 = ON
AMS
348i
Default
1
1-0 transition
0
0-1 transition
0
0
0
1
1
1
0
Unit
CR to
module
metr. Inch
5cd
5a
Leuze electronic

Hide quick links:

Advertisement

Table of Contents
loading