Fast Commissioning / Operating Principle; Mounting The Ams 348; Mounting The Device; Mounting The Reflector - Leuze electronic AMS 348i Manual

Optical laser measurement system
Table of Contents

Advertisement

3

Fast commissioning / operating principle

Notice!
Below, you will find a short description for the initial commissioning of the AMS 348i.
Detailed explanations for the listed points can be found throughout the handbook.
3.1
Mounting the AMS
The AMS
348i
plane-parallel, flat walls.
Figure 3.1:
Attention!
For error-free position measurement, there must be an unobstructed line-of-sight between
the AMS
348i
3.1.1

Mounting the device

The laser is mounted on a vertical wall using 4 screws (M5).
Alignment is performed using 2 adjustment screws. Adjust so that the laser light spot is
positioned at the center of the reflector. The alignment is to be secured with the knurled nut
and locked with the M 5 nut.
Further information can be found in chapter 5.2 and chapter 5.3.
3.1.2

Mounting the reflector

The reflector is mounted on a vertical wall with 4 screws (M 5). The reflector is angled using
the included shims. Incline the reflector by approx. 1°.
Detailed information can be found in chapter 6.4.
Leuze electronic
348i
and the corresponding reflector are mounted on two mutually opposing,
Schematic illustration of mounting
and the reflector.
Fast commissioning / operating principle
AMS
348i
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents