Specifications; Specifications Of The Laser Measurement System; General Specificationsams 348I - Leuze electronic AMS 348i Manual

Optical laser measurement system
Table of Contents

Advertisement

4

Specifications

4.1

Specifications of the laser measurement system

4.1.1
General specificationsAMS
Measurement data
Measurement range
Accuracy
1)
Consistency
Light spot diameter
Measurement value output
Integration time
Resolution
Temperature drift
Ambient temperature sensitivity
Air pressure sensitivity
Traverse rate
Electrical data
2)
Supply voltage Vin
Current consumption
Optical data
Transmitter
Laser class
3)
Laser life expectancy
Interfaces
Interface type
Protocol
Conformance Class
Operating and display elements
Keyboard
Display
LED
Leuze electronic
348i
AMS
348i
40 (H) AMS
0.2 ... 40 m
0.2 ... 120 m
± 2 mm
0.3 mm
40 mm
100 mm
adjustable, see chapter of the individual interfaces
without device heating:  250 mA / 24 V DC
with device heating:  500 mA / 24 V DC
laser diode, red light, wavelength 650 ... 690 nm
average temperature / year
PROFINET-RT with integrated switch
monochromatic graphical display, 128 x 64 pixels
4 LEDs, 2 of which are used to display the PROFINET connection
AMS
348i
348i
120 (H) AMS
348i
0.2 ... 200 m
± 2 mm
± 3 mm
0.5 mm
0.7 mm
 150 mm
1,7 ms
8 ms
 0.1 mm/K
1 ppm/K
0.3 ppm/hPa
 10 m/s
18 ... 30 V DC
2 acc. to EN 60825-1, CDRH
for BUS IN and BUS OUT
PROFINET-RT communication
B
4 buttons
Specifications
200 (H) AMS
348i
300 (H)
0.2 ... 300 m
± 5 mm
1.0 mm
 225 mm
50 °C: 23.000 h
25 °C: 60.000 h
20 °C: 75.000 h
10 °C: 120.000 h
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents