Orange continuous light
BUS LED
Off
Flashing green
Green continuous light
Red flashing
Red continuous light
Orange flashing
Leuze electronic
Display and control panel AMS 348i
Power LED orange
- Configuration via the display
- No data on the host interface
BUS LED off
- No supply voltage (Power)
- No communication possible
- PROFINET communication not initialized or inactive
BUS LED flashes green
- Initialization of the AMS 348i, establishing commu-
nication
BUS LED green
- Network operation ok
- Connection and communication to controller (PLC)
established ("data exchange")
BUS LED flashes red
- Bus error, communication error
- Parameterization or configuration failed ("parameter
failure")
- IO error
- No data exchange
BUS LED red
- Bus error, network error
- No
communication
established ("no data exchange")
BUS LED flashes orange
- PROFINET wave function
AMS
348i
(protocol)
to
Controller