Leuze electronic AMS 348i Manual page 49

Optical laser measurement system
Table of Contents

Advertisement

I/O submenu
Table 8.4:
Level 3
I/O 1
I/O 2
Limit values
Leuze electronic
I/O submenu
Level 4
Level 5
Selection/configuration option
Description
Port config-
Input/Output
uration
Defines whether I/O 1 functions as an output or input.
Switching
Function
No function/preset teach/laser ON/OFF
input
Activation
Low active/High active
Switching
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
output
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching
output.
Activation
Low active/High active
Port config-
Input/Output
uration
Defines whether I/O 2 functions as an output or input.
Switching
Function
No function/preset teach/laser ON/OFF
input
Activation
Low active/High active
Switching
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
output
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching
output.
Activation
Low active/High active
Upper pos.
Activation
ON / OFF
limit 1
Limit value
Value input in mm or inch/100
input
Lower pos.
Activation
ON / OFF
limit 1
Limit value
Value input in mm or inch/100
input
Upper pos.
Activation
ON / OFF
limit 2
Limit value
Value input in mm or inch/100
input
Lower pos.
Activation
ON / OFF
limit 2
Limit value
Value input in mm or inch/100
input
Display and control panel AMS 348i
AMS
348i
Standard
Output
No function
Low active
Plausibility (PLB),
hardware (ERR)
Low active
Output
No function
Low active
Intensity (ATT),
Temp. (TMP),
Laser (LSR)
Low active
OFF
0
OFF
0
OFF
0
OFF
0
46