Leuze electronic AMS 348i Manual page 81

Optical laser measurement system
Table of Contents

Advertisement

9.9.3.23 Module 8: Position limit value range 2
PROFINET module identifier
Module-ID
Submodule-ID
Description
The position limit value range 2 parameter defines a distance range with lower and upper
limits. If the measured value lies outside of the configured range, the corresponding bit is
set in module 6 or, if configured, an output is set.
Parameters
Parameter
Description
a
Specifies the lower position limit.
Lower pos.
limit 2
b
Specifies the upper position limit.
Upper pos.
limit 2
Parameter length: 8 bytes
Input data
None
Output data
None
Leuze electronic
1008
1
Rel.
Data
Value
addr.
type
sign
0...3
-999999 ... +999999
32 bit
sign
4...7
-999999 ... +999999
32 bit
AMS
348i
PROFINET interface
Default
Unit
CR to
module
metr. Inch
0
mm
in/100 –
0
mm
in/100 –
78