PROFINET interface
9.9.3.21 Module 6: Status and control
PROFINET module identifier
Module-ID
Submodule-ID
Description
The module signals various status information of the AMS 348i. The laser can be controlled
via the master's output data.
Parameters
None
Input data
Input data
Description
a
Laser 
Signals the laser status.
status
b
Preset 
Status of the preset value.
status
This bit toggles on each teach event of a
c
preset value.
Preset teach
d
Reserved
If the intensity of the received signal is
e
less than the warning threshold, the
Intensity
status bit is set.
(ATT)
f
If the internal device temperature
exceeds or drops below the set limit
Temperature
value, the status bit is set.
(TMP)
g
Laser prefailure message.
Laser (LSR)
h
If implausible measurement values are
Plausibility
diagnosed, the status bit is set.
(PLB)
i
If a hardware error is diagnosed, the
Hardware
status bit is set.
(ERR)
j
Signals that the value is less than lower
Lower
position limit
limit value 1.
value 1
k
Signals that the value is greater than
Upper
upper limit value 1.
position limit
value 1
75
1006
1
Rel.
Data
Value
addr.
type
0: Laser ON
1.0
Bit
1: Laser OFF
0: Preset not active
1.1
Bit
1: Preset active
1.2
Bit
0 or 1
1.3
Bit
0: OK
1.4
Bit
1: Warning
0: OK
1.5
Bit
1: Temperature above/below
0: OK
1.6
Bit
1: Laser warning
0: OK
1.7
Bit
1: Implausible measurement
0: OK
0.0
Bit
1: Hardware error
0: OK
0.4
Bit
1: Value less than limit
0: OK
0.5
Bit
1: Value greater than limit
AMS
348i
Default
limit
value
Unit
CR to
module
metr. Inch