PROFINET interface
Parameters
Parameter
Description
a
The parameter specifies the resolution
Velocity
for the velocity value.
resolution
b
The parameter specifies the integration
time (averaging time) of the calculated
Average
velocity values.
Parameter length: 2 bytes
Input data
Input data
Description
c
Current velocity.
Velocity
Input data length: 4 bytes consistently
Output data
None
81
Rel.
Data
Value
addr.
type
001=1: 1
0.0
010=2: 10
...
Bit
011=3: 100
0.2
100=4: 1000
101 = 5: free resolution
000=0: 2
001=1: 4
0.3
010=2: 8
...
Bit
011=3: 16
0.5
100=4: 32
101=5: 64
110=6: 128
Rel.
Data
Value
addr.
type
sign
0
-999999 ... +999999
32 bit
AMS
348i
Default
Unit
CR to
module
metr.
Inch
(in/
1
mm/s
100)
20b
/s
3
ms
Default
Unit
CR to
module
metr. Inch
0
scaled