Leuze electronic AMS 348i Manual page 83

Optical laser measurement system
Table of Contents

Advertisement

g
Specifies in the event of an error
whether the velocity immediately
outputs the value of the "velocity in the
Error delay
case of error" parameter or outputs the
(velocity)
last valid velocity for the duration of the
configured "error delay time".
Errors which occur are suppressed for
h
the configured time. If no velocity
position value can be ascertained
during the configured time, the last
Error delay
valid velocity value is output. If the error
time (veloc-
persists after the time elapses, the
ity)
value stored in the "velocity in the case
of error" parameter is output.
Parameter length: 6 bytes
Input data
None
Output data
None
9.9.3.25 Module 10: Velocity
PROFINET module identifier
Module-ID
Submodule-ID
Description
Outputs the current velocity with the configured resolution. The unit (metric or inch) is set
in module 1 (position value) and also applies to the velocity. If module 1 is not configured,
the AMS
348i
The sign of the velocity is dependent on the count direction in module 1d.
In the default setting a positive velocity is output when the reflector moves away from the
AMS 348i. When the reflector moves towards the AMS 348i, negative velocities are output.
If the "negative" count direction is configured in module 1, the velocity signs are reversed.
Measurement value preparation averages all velocity values calculated during the selected
period (averaging) to yield a velocity output value.
Leuze electronic
3.3
4...5
1010
1
operates with the default unit (metric).
0: OFF
Bit
1: ON
unsign
200 ... 1000
16 bit
AMS
348i
PROFINET interface
1
200
ms
80

Hide quick links:

Advertisement

Table of Contents